How to install bus duct connectors to improve work efficiency

Release time:: 2022-03-22 Click count: 743

  The meaning of bus duct connector is a type of bus duct connector,which belongs to the category of bus duct accessories.Bus duct accessories include plug-in box kits,plug-in interfaces,connectors,elbows,flange ends,cable inlet boxes,bus end seals,horizontal brackets,spring brackets,flexible connections,variable capacity joints,etc.Bus duct connectors include two joint side connecting plates,insulation partition groups,and insulation bolts.Bus duct accessories consist of straight sections,elbows,tees,flanges,cable adapter boxes,terminal seals,and plug-in boxes.Connectors are generally included in the quotation for straight sections,brackets are used to buffer the compression of busbars during connection,connectors are used for connection,and copper bars are used to connect the box body of the cabinet and the place where the busbars are connected.The plug-in box is designed for power supply and other purposes according to the requirements on the drawing.

  Bus duct connectors should not be installed inside walls because if they are located inside walls,they cannot be repaired in the future.High humidity can cause rapid oxidation of conductors at the connector,aging of insulation components,and even short-circuit accidents.The function of the busbar connector is only to connect section by section of the busbar duct(including straight sections and bends,etc.)into a whole,just a joint.Because a busbar circuit is usually tens or hundreds of meters long,and the production of busbars can only be done in sections,with a length of only 6 meters per section,it is necessary to transport them to the site and connect each section with connectors.If the bus duct needs to pass through two walls continuously after turning,and the distance between the two walls is more than 500mm and the environment is not too humid,the connector can be set between the two walls.If the distance between the two walls is very close,the connector needs to be set after the bus passes through the two walls.The advantage of the new bus duct connector is that the overall extrusion molding of the insulation partition is only 65%of the original,with fixed torque bolts,which improves work efficiency.Only the insulation partition with bolt holes in the middle improves safety.

  The feature of the new busbar slot connector is that there are insulation partition groups parallel to the insulation of the joint side connecting plate in two joint side connecting plates.The insulation partition group includes two insulation outer partitions and multiple inner partitions.Multiple insulation inner partitions are arranged parallel to each other between the two insulation outer partitions.There is an insulation bolt fixing hole at the corresponding position on the two joint side connecting plates,as well as on the two insulation outer partitions and multiple inner partitions.The insulation bolt is an insulation fixed torque bolt.The insulation fixed torque bolt passes through the bolt fixing holes on the joint side connecting plate,the insulation outer partition,and the multiple inner partitions and is insulated and fixed on the two joint side connecting plates.Between the joint side connecting plate and the insulation outer partition,Insulation sleeves are installed between the insulation outer partition and the insulation inner partition,as well as between adjacent insulation inner partitions,The insulation sleeve is placed on the fixed torque bolt rod at the corresponding position.


Online Service

Hotline

4008-455-828
7*24 Hourly service hotline

WeChat

二维码Scan
Top