Waterproof performance and basic installation knowledge of bus duct

Release time:: 2022-04-16 Click count: 1398

  There may be some issues with the use of bus ducts.To avoid or reduce the impact,it is required to have good waterproof and dustproof installation during installation,so as to ensure that the bus ducts can work well.When installing a bus duct,the first thing to pay attention to is its environmental conditions.Check the humidity in the environment to see if it will affect the operation of the bus duct.Based on the environmental conditions,choose a bus duct with appropriate parameters.To avoid unnecessary malfunctions caused by environmental factors that prevent the bus duct from functioning properly.

  When using waterproof bus ducts,waterproof measures must be taken well,because when water enters the interior of the bus duct,the insulation performance of the bus duct will deteriorate.Long term use in this way can cause short circuits in the bus duct,leading to power supply problems and affecting operation.Although the bus duct itself has good waterproof measures,certain waterproof protective measures should also be taken during installation in case of any unforeseen circumstances.At room temperature,the insulation resistance of each busbar trunking accessory shall not be less than 1000MΩ,and at an ambient temperature of 100℃,the insulation resistance of each busbar trunking accessory shall not be less than 200MΩ.The shell has high impact resistance and can withstand mechanical impacts greater than 20J.

  When the bus duct passes through floors,it is important to find a good wearing point to avoid water leakage between floors due to bad weather,which may affect the use of the bus duct.If the bus duct malfunctions during use,it may also cause damage to the user.Therefore,it is important to pay attention to the waterproof measures of the bus duct no matter where it is used.Alkali proof for outdoor temperatures below 160℃,mechanical processing performance of busbar trunking accessories,and normal operation in deep water above 3000 meters.Cables can still operate when immersed in water,while general bus duct fittings are afraid of water.Even IP54 bus duct fittings are afraid of moisture intrusion,which reduces the insulation function of bus duct fittings.Water is a major obstacle to the use of busbar trunking accessories.

  Waterproof bus ducts are no less impressive than cables,with a shell protection level of IP68.They can be immersed in water for a long time without reducing the insulation resistance of bus duct accessories.Bus duct material is simple,it is a closed metal device composed of copper and aluminum bus columns,used to distribute large power to various components of the distributed system.It has increasingly replaced wires and cables in indoor low-voltage power transmission mainline engineering projects.Compared with traditional cables,it fully demonstrates its superiority in high current transmission.At the same time,due to the adoption of new technologies and processes,the contact resistance and temperature rise at the connection points of the busbar duct and the junction of the distribution port are greatly reduced.High quality insulation materials are used in the busbar duct,thereby improving the safety and reliability of the busbar duct and making the entire system more complete.