After the installation of the bus duct, a safety check should be conducted on the circuit to eliminate hidden dangers

Release time:: 2021-10-25 Click count: 1327

After the installation of the bus duct, a safety inspection of the circuit is required to eliminate potential hazards

Installation of bus ducts and safety inspection requirements for circuits to eliminate potential hazards. Regarding the installation of bus ducts, everyone should also know that they need to be prepared before installing and using bus ducts. However, regular inspections and maintenance are still necessary even after installation and startup. So, how should the inspection be carried out after the installation of the bus duct is completed?

CESKO shares inspection knowledge with you:

Check the operation of the bus duct for leaks, water spray, potential sources of moisture, and biological threats to the entire system. Check the technical equipment and accessories, the cross-sectional design markings should be clear and complete, the appearance should be free of damage or deformation, and the insulation material resistance of the busbar should be greater than 20M Ω. And check if there are any heat sources that affect the temperature rise of the busbar trunking system, check the quantity and specifications of the busbar trunking, and inspect the equipment unpacking point. The installation unit, supervision unit, construction unit, and supplier should jointly classify and file for record. Check if students have any unknown objects that can enter the bus duct, inspect the main components of the bus duct system for defects, corrosion, and whether the elasticity of the brackets is sufficient. Replace immediately after discovering the problem. Then, the equipment and accessories can be checked according to the packing list to ensure that their specifications, quantities, and varieties meet the requirements of educational design development.


1S2A8123.00_00_15_02.Still001

When the busbar is running for a long time, the joint temperature rise should be checked regularly once a year. According to the GB7251 standard, a joint temperature rise of no more than 70K is considered qualified (ambient temperature of 40 degrees). Check whether the connecting bolts and conductor contacts of all busbar joints are loose. Prevent the joint from heating up due to increased resistance caused by looseness. Check the insulation materials and whether there is aging, and whether the conductive parts have melted or deformed. If there is phase to phase connection or insulation breakdown, it should be dismantled in sections and checked with a voltage tester to identify the fault, or the bus duct should be replaced or the insulation coating should be re applied.